AICT-1P-25A Manual Control Contactor
Brief Introduction:
• AICT Series Lighting control device AC Contactor (contactor for short) is mainly designed for AC 50/60HZ circuits with 230/450V rated operating voltage in AC-7A usage, rated operating voltage up to 230V,rated operating current up to 63A
• It functions as long distance breaking and circuit controlling.
• This product is mainly applied to household appliances or low inductance loading and home electromotor loading control used for the similar purpose
Specification
Type Designation |
Connecting Type |
Qnt/Ctn |
MU No |
G/N W/N |
MEAS |
Pcs |
Kg |
(cm)s |
|||
Aict-25(16-25AMP) |
1 Phase, 1NC |
120 |
1 |
16.5/15 |
47*26*18 |
1 Phase, 1NO |
120 |
1 |
16.5/15 |
47*26*18 |
|
1 Phase+1 wire, 2NC |
120 |
1 |
16.5/15 |
47*26*18 |
|
1 Phase+1 wire, 2NO |
120 |
1 |
16.5/15 |
47*26*18 |
|
1 Phase+1 wire, 1NC+1NO |
120 |
1 |
16.5/15 |
47*26*18 |
Normal working and installation Conditions:
• Ambient temperature:-5℃ to +40℃.The average temperature no more than +35℃ in 24 hours.
• Altitude: No more than 2000m.
• Atmospheric condition: the relative humidity of the installation place should be no more than 50% When the maximum temperature is +40℃,If under a lower temperature ,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25℃ and the monthly average maximum relative humidity of this month no more than 90%.Beside, the dew on the surface of products caused by temperature change should be taken into consideration.
• Class of Pollution :Class 2.
• Installation Condition: Class 2
• Installation Mode: Use the installation orbit of “Top Cap” section TH35-7.5 mould
• Mechanical Life:≥1*105times
• Electrical Life:≥3*104times
Specialty:
(Table 1: Types of contactor and relevant data)
Type | Rated insulation voltage(V) | Rated operating voltage(V) | Rated heating current(A) | Rated operating current(A) | Control Power(KW) |
AC1,ACTa,ACTb | 500 | 230 | 100 | 100/40 | 25/6.5 |
AC1,ACTa,ACTb | 500 | 230 | 80 | 80/32 | 20/5 |
AC1,ACTa,ACTb | 500 | 230 | 63 | 63/25 | 13/3.8 |
AC1,ACTa,ACTb | 500 | 230 | 40 | 40/15 | 8.4/2.4 |
AC1,ACTa,ACTb | 500 | 230 | 32 | 32/12 | 6.5/1.9 |
AC1,ACTa,ACTb | 500 | 230 | 25 | 25/8.5 | 5.4/1.5 |
AC1,ACTa,ACTb | 500 | 230 | 20 | 20/7 | 4/1.2 |
AC1,ACTa,ACTb | 500 | 230 | 16 | 16/5.5 | 3.5/1.2 |
(Table 2: Switching on and segmenting ability)
Type | Switching on and segmenting condition | Pick-up time(s) | Interval(s) | Operation frequency | ||
Ic/Ie | Ur/Ue | Cos∮ | ||||
AC-1,AC-7a | 1.5 | 1.05 | 0.8 | 0.05 | 10 | 50 |
AC-7b | 8 | 1.05 | 0.45 | 0.05 | 10 | 50 |
(Table 3: Operating performance)
Type | On condition | Segment condition | Pick-up time(s) | Interval(s) | Operation frequency | ||||
l/le | U/Ue | Cos∮ | Ic/Ie | Ur/Ue | Cos∮ | ||||
AC-1 | 1.0 | 105 | 0.8 | 1.0 | 105 | 0.8 | 0.05 | 10 | 6000 |
AC-7a | 1.0 | 1.05 | 0.8 | 1.0 | 1.05 | 0.8 | 0.05 | 10 | 30000 |
AC-7b | 6.0 | 1.0 | 0.45 | 6.0 | 1.0 | 0.45 | 0.05 | 10 | 30000 |
Connection Diagrams & Dimensions:
…