NM-2NRJ4 Relay Module

NM-Series
Relay modules are mainly small electromagnetic relays, supplemented with power relays, terminal-type module interface devices with instruction and protection function. Input protection; output over-voltage protection; output over-current protection. It is widely used in the interface between peripheral devices, control signals and adjustment device of automation process to achieve matching of frequency and power.
Graphic symbols of electromagnetic relay
Coil and contact symbols are shown in the figure below:

  1. The series of relay products include DC coil and AC coil. Contacts include 1-pole NO, NC, transfer;
  2. Note them when ordering if you need over-voltage protection, slow flow protection, over-current protection (over-voltage and over-current protection can be chosen at the same time; 2-pole or over 2-pole of relay contacts can only add slow flow protection);
  3. Conventional products have AC and DC input, voltage range: 24VAC/DC;
  4. Customed voltage range: 3-48VDC, 110VAC, 220VAC(380VAC in R & D);
  5. Relay module with over 16 groups can be customized;
  6. Wiring diagram of relay module: an example of 24VDC/A.


VV for common input terminal, A, B for the control terminal;
When: VV input 24VDC positive, A and B for 24VDC negative;
When: VV input 24VDC negative, A and B for 24 VDC positive;
24VAC input same as 24VDC;
Input A and B control relays A and B respectively;
Input method of 4 groups, 8 groups, 16 groups are all the same, please refer to this.

Type NM-2NRJ4 1C  DC24 NM-2NRJ4 2C  DC24 NM-2NRJ4 4C  DC24
Specification 24VDC/AC-1C 2x24VDC/AC-1C 4x24VDC/AC-1C
Size(L x W x H) 90x18x72mm 90x34x72mm 90x66x72mm
Technical data
Input signal
Rated voltage 24VDC/AC 24VDC/AC 24VDC/AC
Max voltage 110% rated value 110% rated value 110% rated value
Rated current 21.8mA 21.8mA 21.8mA
Operating voltage 80% rated voltage 80% rated voltage 80% rated voltage
Resetting voltage 10% rated voltage 10% rated voltage 10% rated voltage
Consumption power ≈0.36W ≈0.36W ≈0.36W
Output contact 1 group 2 group 4 group
Contact type 1-pole transfer for single contact 1-pole transfer for each single contact 1-pole transfer for each single contact
Contact load 8A250VAC/5A28VDC 8A250VAC/5A28VDC 8A250VAC/5A28VDC
Max transfer voltage 380VAC/125VDC 380VAC/125VDC 380VAC/125VDC
Max transfer power 2500VAC/300W 2500VAC/300W 2500VAC/300W
Max operating frequency 1800 times/h 1800 times/h 1800 times/h
Mechanical life 2×10,000,000 operations 2×10,000,000 operations 2×10,000,000 operations
Electrical life 1×100,000 operations 1×100,000 operations 1×100,000 operations
Net weight 50g 90g 165g
Wiring diagramNote: Input voltage can be customized, see instruction for details; an example of 24V  
Fill out my online form.