NIR610 Variable Frequency Drive
NIR610 frequency inverter are single-phase 220 VAC and three-phase 380 VAC compact inverters launched to meet market demand. It adopts V/F control method and speed sensorless vector control method (SVC), and has significant advantages such as high power density, high EMC specification design, and high protection performance.
- Power range0.75kW~2.2kW
- Voltage levelAC 1PH 220V
- AC 3PH 380V
Model Description
Has advanced open-loop vector control performance and good voltage and current control technology;
●Starting torque: 0.5Hz/150% torque;
●Wide voltage range design, the wide voltage range reaches AC 3PH: 320V~450V;
●Has the function of not shutting down in case of instantaneous power failure;
●It has functions such as motor speed tracking technology, PID control, high and low frequency operating mode switching, and intelligent rapid acceleration and deceleration adjustment.
Technical Parameters
Project NIR610 series |
Technical Parameters |
||||
Enter |
Rated voltage,frequency |
3PH AC380V,50Hz/60Hz1PH AC220V,50Hz/60Hz |
|||
Voltage allowable variation range |
3PH AC320V~450V1PH AC190V~250V |
||||
Output |
Voltage |
0~440V0~220V |
|||
Frequency |
Low frequency mode:0~300Hz High frequency mode:0~3000Hz |
||||
Overload capacity |
110% long term 150% 1 minute 200% 4 seconds |
||||
Control method |
V/F control, advanced V/F control, V/F separation control, PG-free current vector control |
||||
Control characteristics |
Frequency settingresolution |
Analog input |
0.1% of maximum output frequency |
||
Digital settings |
0.01Hz |
||||
Frequency accuracy |
Analog input |
Within 0.2% of the maximum output frequency |
|||
Digital input |
Within 0.01% of the set output frequency |
||||
V/F control |
V/F curve (voltage frequency characteristics) |
The base frequency can be set arbitrarily at 0.5~300Hz, the multi-point V/F curve can be set arbitrarily, and various fixed curves such as constant torque, reduced torque 1, reduced torque 2, and square torque can also be selected. |
|||
Torque boost |
Manual setting: 0.0~30.0% of rated outputAutomatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters |
||||
Automatic current limiting and pressure limiting |
Whether during acceleration, deceleration or stable operation, it can automatically detect the motor stator current and voltage, and suppress it within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping. |
||||
Inductive vector control |
Voltage frequency characteristics |
Automatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm |
|||
Torque characteristics |
Starting torque:150% rated torque at 3.0Hz (VF control)150% rated torque at 1.0Hz (advanced VF control)150% rated torque at 0.5Hz (no PG current vector control)Operating speed steady-state accuracy: ≤±0.2% rated synchronous speedSpeed fluctuation: ≤±0.5% rated synchronous speedTorque response: ≤20ms (without PG current vector control) |
||||
Self-determination of motor parameters |
Without any restrictions, automatic parameter detection can be completed under both static and dynamic conditions of the motor to obtain the best control effect. |
||||
Current and voltage suppression |
Full current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression functions |
||||
Undervoltage suppression during operation |
Especially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy. |
||||
Typical functions |
Multi-speed and swing frequency operation |
16-segment programmable multi-segment speed control, multiple operating modes available.Swing frequency operation: preset frequency and center frequency are adjustable, state memory and recovery after power outage |
|||
PID controlRS485 communication |
Built-in PID controller (frequency can be preset).Standard configuration RS485 communication function, with linkage synchronous control function |
||||
Frequency setting |
Analog input |
DC voltage 0~10V, DC current 0~20mA (upper and lower limits optional) |
|||
Digital input |
Operation panel setting, RS485 interface setting, UP/DW terminal control, and various combination settings with analog input |
||||
Output signal |
Digital output |
2 Y terminal open collector outputs and 2 programmable relay outputs (TA, TB, TC), up to 61 meaning options |
|||
Analog output |
2 analog signal outputs, the output range can be flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency. |
||||
Acceleration and deceleration time setting |
0.1s~3600.0min can be set continuously, S-shaped and linear modes are optional |
||||
Low noise operation |
Carrier frequency is continuously adjustable from 1.0KHz to 16.0KHz |
||||
Protective function |
Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc. |
||||
Environment |
Place of use |
Indoor, no direct sunlight, no corrosion, no flammable gas, no oil mist, dust, etc. |
|||
Ambient temperature |
-10℃~+40℃(The ambient temperature is between 40℃ and 50℃, please derate it for use.) |
||||
Ambient humidity |
5%~95%RH,No water droplets condensation |
||||
Altitude |
Derate for use above 1000 meters, and derate by 10% for every 1000 meters. |
||||
Structure |
Protection level |
IP20 |
|||
Cooling method |
Air-cooled, with fan control |
||||
Installation method |
Wall-mounted |
||||
…

English
简体中文
RU
PT



