ASC1 1P/2P 100A Modular Contactors

ASC1 1P/2P 100A Modular ContactorsASC1 1P/2P 100A Modular Contactors

Brief Introduction:

• ASC1 Series AC Contactor (contactor for short) is mainly designed for AC 50/60HZ circuits with 230/450V rated operating voltage in AC-7A usage, rated operating voltage up to 230V,rated operating current up to 63A

• It functions as long distance breaking and circuit controlling.

• This products is mainly applied to household appliances or low inductance loading and home electromotor loading control used for the similar purpose.

 

 

 

 

 

Technical Data

Type Designation

Connecting Type

Qnt/Ctn

MU No

G/N W/N

MEAS

Pcs

Kg

(cm)s

ASC1-100

(80-100AMP)

3 Phase, 3NC

20

6

13.5/12.5

47*26*18

3 Phase, 3NO

20

6

13.5/12.5

47*26*18

3 Phase, 2NO+1NC

20

6

13.5/12.5

47*26*18

3 Phase, 2NC+1NO

20

6

13.5/12.5

47*26*18

3 Phase + Four wire, 4NC

20

6

13.5/12.5

47*26*18

3 Phase + Four wire, 4NO

20

6

13.5/12.5

47*26*18

3 Phase + Four wire, 3NO+1NC

20

6

13.5/12.5

47*26*18

3 Phase + Four wire, 1NO+3NC

20

6

13.5/12.5

47*26*18

3 Phase + Four wire, 2NC+2NO

20

6

13.5/12.5

47*26*18

Normal working and installation Conditions:

· Ambient temperature:-5℃ to +40℃.The average temperature no more than +35℃ in 24 hours.

· Altitude: No more than 2000m.

· Atmospheric condition: the relative humidity of the installation place should be no more than 50% When the maximum temperature is +40℃,If under a lower temperature ,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25℃ and the monthly average maximum relative humidity of this month no more than 90%.Beside, the dew on the surface of products caused by temperature change should be taken into consideration.

· Class of Pollution :Class 2.

· Installation Condition: Class 2

· Installation Mode: Use the installation orbit of “Top Cap” section TH35-7.5 mould

· Mechanical Life:≥1*105times

· Electrical Life:≥3*104times

  Specialty:

(Table 1: Types of contactor and relevant data)

Type

Rated insulation voltage(V)

Rated operating voltage(V)

Rated heating current(A)

Rated operating current(A)

Control Power(KW)

AC1,ACTa,ACTb

500

230

100

100/40

25/6.5

AC1,ACTa,ACTb

500

230

80

80/32

20/5

AC1,ACTa,ACTb

500

230

63

63/25

13/3.8

AC1,ACTa,ACTb

500

230

40

40/15

8.4/2.4

AC1,ACTa,ACTb

500

230

32

32/12

6.5/1.9

AC1,ACTa,ACTb

500

230

25

25/8.5

5.4/1.5

AC1,ACTa,ACTb

500

230

20

20/7

4/1.2

AC1,ACTa,ACTb

500

230

16

16/5.5

3.5/1.2

(Table 2: Switching on and segmenting ability)

Type

Switching on and segmenting condition

Pick-up time(s)

Interval(s)

Operation frequency

Ic/Ie

Ur/Ue

Cos

AC-1,AC-7a

1.5

1.05

0.8

0.05

10

50

AC-7b

8

1.05

0.45

0.05

10

50

(Table 3: Operating performance)

Type

On condition

Segment condition

Pick-up time(s)

Interval(s)

Operation frequency

l/le

U/Ue

Cos

Ic/Ie

Ur/Ue

Cos

AC-1

1.0

105

0.8

1.0

105

0.8

0.05

10

6000

AC-7a

1.0

1.05

0.8

1.0

1.05

0.8

0.05

10

30000

AC-7b

6.0

1.0

0.45

6.0

1.0

0.45

0.05

10

30000

Connection Diagrams & Dimensions:

ASC1 1P/2P 100A Modular Contactors