ACF1-09 AC Contactor
Application
ACF1 series AC contactors are suitable for frequency 50/60Hz, rated insulation voltage up to 1000V,rated operation current 9~475A under AC-3 duty. It is mainly used for making/breaking electric circuit at a long distance & for frequent starting/stopping & with thermal relay to compose a magnetic motor starter. The product conforms to IEC60947-4-1 standard.
Specification
Type | ACF1-09 ACF1-12 |
ACF1-16 ACF1-22 |
ACF1-32 | ACF1-45 ACF1-63 |
ACF1-75 ACF1-85 |
ACF1-110 ACF1-140 |
ACF1-170 ACF1-205 |
ACF1-250 ACF1-300 |
ACF1-400 ACF1-475 |
|
Mechanical endurance(x106) | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | |
Conventional thermal current(A) | 20 | 30 | 45 | 80 | 100 | 160 | 210 | 300 | 400/550 | |
Rated insulation voltage(V) | 660 | 660 | 660 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated(380V)operating current(A) | AC-3 | 9/12 | 16/22 | 32 | 45/63 | 75/85 | 110/140 | 170/205 | 250/300 | 400/475 |
AC-4 | 3.3/4.3 | 7.7/8.5 | 15.6 | 24/28 | 34/42 | 54/68 | 75/96 | 110/125 | 150 | |
Power of controllable motor(kW)AC-4 | 380V | 4/5.5 | 7.5/11 | 15 | 22/30 | 37/45 | 55/75 | 90/110 | 132/160 | 200/250 |
660V | 5.5/7.5 | 11 | 32 | 39/55 | 67 | 100 | 156 | 235 | 375 | |
Power of controllable motor(kW)AC-4 | 380V | 1.4/1.9 | 3.5/4 | 7.5 | 12/14 | 17/21 | 27/35 | 38/50 | 58/66 | 81 |
660V | 2.4/3.3 | 6/6.6 | 13 | 20.8/24 | 29.5/36 | 46.9/60 | 66/86 | 100/114 | 140 | |
Frequency of operation(l/H) | AC-3 | 1000 | 750 | 750 | 1200/1000 | 1000/850 | 1000/750 | 700/500 | 700/500 | 500/420 |
AC-4 | 250 | 250 | 250 | 400/300 | 300/200 | 300/200 | 200/130 | 200/130 | 150 | |
Electrical endurance(x106) | AC-3 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
AC-4 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |
Operating voltage range of coil | (0.8~1.1)Ue | |||||||||
Power consumption | Atracting(VA) | 10 | 10 | 12.1 | 17 | 32 | 39 | 58 | 84 | 115 |
Starting(VA) | 68 | 69 | 101 | 183 | 330 | 550 | 910 | 1460 | 2450 | |
Ratedinsulation voltage of auxitiary contacts(V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | |
Conventional thermal current of auxitiary contacts | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
Rated operating current of auxitiary cpntacts(A) | AC15 380/220 |
6/10 | 6/10 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
DC13 220V |
0.45 | 0.45 | 0.48 | 0.48 | 0.48 | 0.48 | 0.48 | 0.48 | 0.48 | |
Rated voltage of the control coil(V) | 50Hz | 24,36,48,110,127,220,380,etc. | ||||||||
60Hz | 24,110,220,440,etc. |
Outline and Mounting Dimension
…